Technical Data
Wall mounted unit
EEDEN16
FTXJ-MS, FTXJ-MW
Downloaded from www. Manualslib. com manuals search engine
Downloaded from www. Manualslib. com manuals search engine
• Indoor Unit • FTXJ-MS, FTXJ-MW
TABLE OF CONTENTS FTXJ-MS, FTXJ-MW
1 2 3 4 5 6 7 8
Features . .
Wiring Diagrams - Single Phase Sound Pressure Spectrum
11 . [. . . ] kW kW
0. 023 0. 031 0. 033 Silver 0. 042
0. 033 0. 043 0. 031
0. 023 0. 033 White 303/998/212 322/1, 101/389 12 16 4 610 2 1. 2 18 Ø6, 35 Hi-XB Multi slit fin 0. 042
0. 033 0. 043
3
2
Removable / washable / mildew proof Cross flow fan 8. 9 313 6. 6 234 4. 4 155 2. 6 91 10. 2 361 8. 4 298 6. 3 223 3. 8 133 11. 0 388 8. 6 303 7. 8 276 4. 8 168 2. 9 102 12. 4 438 9. 6 340 6. 9 245 4. 1 144 10. 9 385 8. 9 313 6. 8 239 3. 6 128 12. 6 446 10. 5 372 8. 1 284 5. 0 176 KFD-280-40-8G1 5 + silent, + auto 1, 440/1, 140/840/600 1, 710/ 1, 710/ 1, 300/890/ 1, 440/ 640 1, 160/740 1, 440/1, 140/840/600 1, 710/ 1, 710/ 1, 300/890/ 1, 440/ 640 1, 160/740 10. 2 361 8. 4 298 6. 3 223 3. 8 133 8. 9 313 6. 6 234 4. 4 155 2. 6 91 11. 0 388 8. 6 303 7. 8 276 4. 8 168 2. 9 102 12. 4 438 9. 6 340 6. 9 245 4. 1 144 10. 9 385 8. 9 313 6. 8 239 3. 6 128 12. 6 446 10. 5 372 8. 1 284 5. 0 176
1, 620/ 1, 380/ 1, 100/760
1, 720/ 1, 400/ 1, 100/760
1, 910/ 1, 540/ 1, 180/800
1, 940/ 1, 660/ 1, 330/920
1, 620/ 1, 380/ 1, 100/760
1, 720/ 1, 400/ 1, 100/760
1, 910/ 1, 540/ 1, 180/800
1, 940/ 1, 660/ 1, 330/920
29 54 56 38/32/25/19 40/34/28/ 19 41/34/28/ 19 59 59 45/34/26/ 20 45/37/29/ 20 60 60 46/40/35/ 32 47/41/35/ 32 54 56 38/32/25/19 40/34/28/ 19 41/34/28/ 19 59 59 45/34/26/ 20 45/37/29/ 20 60 60 46/40/35/ 32 47/41/35/ 32
High/Nom. /Low/ Silent operation Infrared remote control
ARC466A9 Microcomputer control Right, Left, Horizontal, Downward
• Split - Sky Air • FTXJ-MS, FTXJ-MW
Downloaded from www. Manualslib. com manuals search engine
3
• Indoor Unit • FTXJ-MS, FTXJ-MW
2
Specifications
Standard Accessories : Operation manual; Quantity : 1; Standard Accessories : Installation manual; Quantity : 1; Standard Accessories : Infrared remote control; Quantity : 1; Standard Accessories : Batteries; Quantity : 2; Standard Accessories : Remote control holder; Quantity : 1; Standard Accessories : Fixing screws for mounting plate; Quantity : 5; Standard Accessories : Mounting plate; Quantity : 1; Standard Accessories : Titanium apatite photocatalytic air purification filter; Quantity : 2; Standard Accessories : Fixing screw for remote controller holder; Quantity : 2; Standard Accessories : Indoor unit fixing screws; Quantity : 2; Standard Accessories : Screw cover; Quantity : 2; Standard Accessories : Wlan adapter kit; Standard Accessories : Titanium apatite filters; Quantity : 2;
2
2-2 Electrical Specifications
Power supply Name Phase Frequency Voltage Current Notes SL: The silent fan level of the air flow rate setting Nominal running Cooling current (RLA) - 50Hz Heating Hz V A A
FTXJ20MS
FTXJ25MS
FTXJ35MS
FTXJ50MS
FTXJ20MW
FTXJ25MW
FTXJ35MW
FTXJ50MW
V1 1~ 50 220-240 0. 12 0. 15 0. 16 0. 21 0. 16 0. 22 0. 15 0. 12 0. 16 0. 21 0. 16 0. 22
4
• Split - Sky Air • FTXJ-MS, FTXJ-MW
Downloaded from www. Manualslib. com manuals search engine
• Indoor Unit • FTXJ-MS, FTXJ-MW
3
3-1
Options
Options
3
3
FTXJ-MW FTXJ-MS
Option kit
Wired remote control Extension cord for wired remote control (3m) Extension cord for wired remote control (5m) Centralised control board (up to 5 rooms) Wiring adaptor (normal open contact - normal open pulse contact) Interface adaptor for DIII-NET Central remote control Unified ON/OFF controller Schedule timer Titanium apatite photocatalytic air-purifying filter with frame Anti-theft protection for remote control
FTXJ-MW_S
BRC073A1 BRCW901A03 BRCW901A08 KRC72A KRP413AB1S KRP928BB2S DCS302CA51 DCS301BA51 DST301BA51 KAF970A46 KKF910AA4
Remark
①
Notes
1. R32 models
Legend ① Three-dimensional knitted fabric (42x255mm) + activated charcoal net
3D095173C
• Split - Sky Air • FTXJ-MS, FTXJ-MW
Downloaded from www. Manualslib. com manuals search engine
5
• Indoor Unit • FTXJ-MS, FTXJ-MW
4
4-1
Dimensional Drawings
Dimensional drawings
4
>
>
>
>
6
• Split - Sky Air • FTXJ-MS, FTXJ-MW
Downloaded from www. Manualslib. com manuals search engine
• Indoor Unit • FTXJ-MS, FTXJ-MW
5
5-1
Centre of gravity
Centre of Gravity
3
5
• Split - Sky Air • FTXJ-MS, FTXJ-MW
Downloaded from www. Manualslib. com manuals search engine
7
• Indoor Unit • FTXJ-MS, FTXJ-MW
6
6-1
Piping Diagrams
Piping diagrams
6
6. 4CuT
6. 4CuT 9. 5CuT
M
9. 5CuT
8
• Split - Sky Air • FTXJ-MS, FTXJ-MW
Downloaded from www. Manualslib. com manuals search engine
• Indoor Unit • FTXJ-MS, FTXJ-MW
6
6-1
Piping diagrams
Piping Diagrams
3
6
6. 4CuT
6. 4CuT 12. 7CuT
M
9. 5CuT
• Split - Sky Air • FTXJ-MS, FTXJ-MW
Downloaded from www. Manualslib. com manuals search engine
9
• Indoor Unit • FTXJ-MS, FTXJ-MW
7
7-1
Wiring diagrams
Wiring Diagrams - Single Phase
7
10
• Split - Sky Air • FTXJ-MS, FTXJ-MW
Downloaded from www. Manualslib. com manuals search engine
• Indoor Unit • FTXJ-MS, FTXJ-MW
8
8-1
Sound data
Sound Pressure Spectrum
FTXJ20MW FTXJ20MS
Cooling mode Heating mode
3
90
NR90 NR85 NR80 NR75 NR70 NR65 NR60 NR55 NR50 NR45 NR40 NR30 NR25 NR0 NR5 NR10 NR15 NR20 NR35
90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 63 125
80 70 60
Sound pressure level [dB]
50 40 30 20 10 dBA
90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 63 125
90
NR90 NR85 NR80 NR75 NR70 NR65 NR60 NR55 NR50 NR45 NR40 NR35 NR30 NR25 NR0 NR5 NR10 NR15 NR20
80 70 60 50 40 30 20 10 dBA
8
Sound pressure level [dB]
250
500
1000 2000 4000 8000
250
500
1000 2000 4000 8000
Octave band centre frequency [Hz] Legend dBA = A-weighted sound pressure level (A scale according to IEC). A Scale Cooling B C Location of microphone dBA Notes 1 2 3 4 5
. .
Octave band centre frequency [Hz]
Total dB B 38 C 25
Heating
Total dB
A
A dBA
B 40
C 28
Operating conditions: power source 220-240 V/220 V 50/60 Hz; JIS standard Background noise already taken into account. Operating noise varies depending on operation and ambient conditions. The operation noise measuring method is in accordance with JISC9612. Measuring location: anechoic chamber
3D092362A
FTXJ25MW FTXJ25MS
Cooling mode Heating mode
90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 63 125
90
NR90 NR85 NR80 NR75 NR70 NR65 NR60 NR55 NR50 NR45 NR40 NR35
80 70 60
Sound pressure level [dB]
50 40 30 20 10 dBA
NR30 NR25 NR0 NR5 NR10 NR15 NR20
250
500
1000 2000 4000 8000
90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 63
90
NR90 NR85 NR80 NR75 NR70 NR65 NR60 NR55 NR50 NR45 NR40 NR35 NR30 NR25 NR0 NR5 NR10 NR15 NR20
80 70 60 50 40 30 20 10 dBA
Sound pressure level [dB]
125
250
500
1000 2000 4000 8000
Octave band centre frequency [Hz] Legend dBA = A-weighted sound pressure level (A scale according to IEC). A Scale Cooling B C Location of microphone dBA Notes 1 2 3 4 5
. .
Octave band centre frequency [Hz]
Total dB B 38 C 25
Heating
Total dB B 41 C 28
A
A dBA
Operating conditions: power source 220-240 V/220 V 50/60 Hz; JIS standard Background noise already taken into account. Operating noise varies depending on operation and ambient conditions. [. . . ] explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N. V.
BARCODE
Daikin products are distributed by:
Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www. daikin. eu - BE 0412 120 336 - RPR Oostende
Downloaded from www. Manualslib. com manuals search engine